inverter felicity IVEM5048-LV - 48v - 5kw
felicity
Category :
IVEM3048/5048-LV Inverter SPECIFICATIONS
| Model | IVEM3048-LV | IVEM5048-LV |
| Rated Output Power | 3000VA | 5000VA |
| 3000W | 5000W | |
| Nominal DC Input Voltage | 48V | 48V |
| Output Voltage Waveform | Pure sine wave | |
| Nominal Output Voltage | 110Vac±5% | |
| Nominal Output Frequency (Hz) | 50±0.3Hz/60Hz±0.3Hz(Adjustable) | |
| Parallel capability | No | Yes,up to 12 units |
| Peak Efficiency | 93% | |
| Over-Load Protection(SMPS load) | 5.5s@≥150% load; 11s@105%~150% load | |
| Surge Rating | 2* rated power for 5s | |
| Capable of Starting Electric | Yes | |
| Output Short Circuit Protection | Yes | |
| General Specifications | ||
| Operating Temperature | -10℃~55C° | |
| Range Storage Temperature | -15C°~60C° | |
| Net Weight (Kg) | 11.9KG | 13.1KG |
| Product Size (D*W*H) | 440*328*130mm | 550*431.5*213mm |
| Package Dimension (D*W*H) | 542*400*224mm | 562*443.5*231mm |
| Utility Charge Mode Specifications | ||
| Nominal Input Voltage | 110Vac | |
| Input Voltage Range | 65-140Vac | |
| Nominal Output Voltage | Dependent on battery type | |
| Max. Charge Current | 60A | 100A |
| Charge Current Regulation | 10-100A (Adjustable unit is 1A) | |
| Over Charge Protection | Yes | |
| Solar Charging & Grid Charging | ||
| Max. PV Open Circuit Voltage | 500V | |
| PV Voltage Range | 90V-500V | |
| Max. Input Power | 4000W | 6000W |
| Max. Solar Charging Current | 60A | 100A |
| Max. Charging Current (PV+Grid) | 60A | 100A |
| Max. Input Current | 15A | 30A |
| Min. Startup Voltage | 100V | |